FRM220A-GSW/SNMP Gigabit Switch / SNMP Controller

Page 2

Chapter 1 Introduction 1.7 GSW/SNMP (Aggregate Switch) FRM220A must be ordered with an aggregate Card. The card is placed in the rear of the chassis

Page 3

Chapter 1 Introduction 11 1.9 FRM220A Fault Handling The FRM220A management is designed is such a way as to minimize any disruption to normal traffi

Page 4

Chapter 1 Introduction 1.10 FRM220A Application The FRM220 is an excellent choice for complimenting fiber infrastructure in Metro LAN, campus, corpo

Page 5 - Table of Contents

Chapter 2 Provisioning Chapter 2 Telnet Provisioning 2.1 Introduction This chapter will go into the details of the specific provisioning and opera

Page 6

Chapter 2 Provisioning 2.2.2 Telnet Login To enter "Telnet mode", a user ID (default is admin) is required and a password may be required

Page 7

Chapter 2 Provisioning 15 2.2.3 TCP/IP Configuration The Network Management modes that require TCP/IP communications must first have all TCP/IP conf

Page 8

Chapter 2 Provisioning From the System Status and Configuration menu, type ‘2’, System Configuration. << System Configuration >> <

Page 9

Chapter 2 Provisioning 17 Step Two: Manager Configuration Process a.) Assign Managers and Trap receivers From the main menu, press the 'U&

Page 10 - Chapter 1 Introduction

Chapter 2 Provisioning 18 2.2.4 Chassis Information and Alarm setup The FRM220A supports two user configurable alarms for a number of different ala

Page 11

Chapter 2 Provisioning 19 For an example of configuration for Alarm #2, press '2' (two). Set Alarm 2 Mode. <0> Disable &l

Page 13 - Chapter 2 Provisioning

Chapter 2 Provisioning 20 2.2.5 User Password Setup From the main menu page, press the 'S' key to enter the System Status and Configuratio

Page 14

Chapter 3 Web Based Management Chapter 3 Web Based Management 3.1 Introduction This chapter will explain the operation of the FRM220A-GSW/SNMP Web

Page 15

Chapter 3 Web Based Management 3.2.2.2 Home Page The Web GUI behaves just like any other web based application. The following graphic shows all of t

Page 16

Chapter 3 Web Based Management 3.2.4 SNMP Configuration Clicking on the "SNMP Configuration" item will display an over

Page 17

Chapter 3 Web Based Management 3.2.6 System The system settings include informational as well as configuration setting. Each item will be explained

Page 18

Chapter 3 Web Based Management 3.2.6.5 Password Setup Enter the old password, if there is one, and enter new password twice. Click “Save”. 3.2.

Page 19

Chapter 3 Web Based Management 3.2.6.9 Event Log The event log keeps a running record of events that happen in the FRM220A-GSW/SNMP, including cards

Page 20

Chapter 3 Web Based Management 3.2.6.14 Reset All Line Cards The reset all line cards function will do a warm reboot of all line cards installed and

Page 21 - 3.1 Introduction

Chapter 3 Web Based Management 3.2.7.3 Traffic The ‘Traffic’ tab will display the RMON traffic counters for each port.

Page 22

Chapter 3 Web Based Management 3.2.8 Ports Aggregation There are 8 (eight) aggregation groups that can be assigned any of the 28 availab

Page 23

CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu District Taipei 114 Taiwa

Page 24

Chapter 3 Web Based Management 30 This page left blank intentionally.

Page 25

Chapter 4 Troubleshooting Chapter 4 Troubleshooting 4.1 Network Settings 4.1.1 Review TCP/IP Settings During unit startup, the LED ‘Matrix’ will fl

Page 26

Chapter 4 Troubleshooting 4.1.2 Review Manager Settings For SNMP management software to connect to the GSW for management, the GSW/SNMP must be prop

Page 27

Appendix A Appendix A. FRM220A Cards Options A.0 Introduction The FRM220A In-Band Managed Media Converter Chassis is designed to accept a variety of

Page 28

Appendix A Specifications  G.703 Interface  Connector HDB26 Female with adapters for 75 or 120 Ohm  Data rate 2048kb/s  Impedance 75 ohm

Page 29

Appendix A The “LAN port” supports auto-negotiation or forced mode setting. If force mode setting the card, be sure to properly configure the GSW por

Page 30

Appendix A The iMUX has an integral “BERT” function to performance test any one of the E1 lines, one at a time. Enable the function, select the E1 li

Page 31 - Chapter 4 Troubleshooting

Appendix A A.2 FRM220A-E1/Data DSU/CSU Converter Card The FRM220A-E1/Data is a single port G.703/704 Fractional E1 DSU/CSU card for the FRM220/220A S

Page 32

Appendix A A.2.1 Web Management The “E1 Port” tab displays status and information and also sets up the framing and timeslot assignment. The frame mod

Page 33 - Appendix A

Appendix A 39 When the E1/DATA is ordered with a V.35 interface, the unit comes with a HDB26 male to MB34 Female adapter cable, 1 meter long. The pin

Page 34

Legal The information in this publication has been carefully checked and is believed to be entirely accurate at the time of publication. CTC Union T

Page 35

Appendix A 40 When the E1/DATA is ordered with a RS-530 interface, the unit comes with a HDB26 male to DB25 Female adapter cable, 1 meter long. The p

Page 36

Appendix A 41 When the E1/DATA is ordered with a RS-449 interface, the unit comes with a HDB26 male to DB37 Female adapter cable, 1 meter long. The p

Page 37

Appendix A 42 When the E1/DATA is ordered with a X.21 interface, the unit comes with a HDB26 male to DB15 Female adapter cable, 1 meter long. The pin

Page 38

Appendix A A.3 FRM220A-Eoe1 Ethernet over E1 Converter The FRM220A-Eoe1 is a single port G.703/704 Fractional E1 DSU/CSU card with built-in HDLC Brid

Page 39

Appendix A A.3.1 Web Management Eoe1 “E1 Port” tab contains the status and E1 parameter settings. The status fields will report Signal normal or LOS,

Page 40

Appendix A A.4 FRM220A-1000EAS/X In-band (802.3ah) Managed Fiber Gigabit Media Converter 1000EAS/X is an IEEE802.3ah OAM/IP compliant in-band managed

Page 41

Appendix A A.4.1 Functional Details Ethernet The 1000EAS/X is based on a L2 switch chip which supports non-blocking switching fabric with up to 1024

Page 42

Appendix A 47

Page 43

Appendix A 48 Local Rx fiber Broken Remote Power Failure LED Status Indicators LED Function State Status PWR Power indicator On Co

Page 44

Appendix A A.4.2 Block Diagram of 1000EAS/X Switch SFP μP RS485 driver Reg. Edge Connector 12VDC MII LEDs Card Face 10/100/1000M SFP 10

Page 45

Table of Contents i Chapter 1 Introduction...

Page 49

Table of Contents ii

Page 50

Chapter 1 Introduction Chapter 1 Introduction 1.0 Introduction Thank you for choosing the FRM220A Ethernet Aggregate Fiber Media Converter Rack. If

Page 51

Chapter 1 Introduction 1.4 Chassis Front Description The front of FRM220A contains the line card slots. They are numbered 1 through 20, from left to

Page 52

Chapter 1 Introduction 9 1.6 Chassis Specifications Environment Temperature -10 - 50°C (14-122°F) Humidity 5-95% non condensing Alarm relay cont