Chapter 5 Operation
76
5.10.1 External Clock Config
User can select OOS or IS to turn on or off the external clock input.
If the EOC connection fails or the External clock module is not installed, the configuration settings will not
appear.
EXT CLK pin assignment
Pin 1 and Pin 2 of RJ-45 are used for E1 PCM data or TTL Clock input
(front view of RJ45 type connector of FMUX01A+)
System Name: External Clock Config and Monitoring
[F1] <Local>
External Clock Module Service : OOS
[F3] <Remote>
External Clock Module Service : OOS
+-------------------------------------------------------+
| Next[F2] Back[ESC] |
+-------------------------------------------------------+