Chapter 5 Operation
84
There are five types of PM:
1. CurrQuart (Current 15 minute interval)
2. HistQuart (History Quarter)
3. CurrDay (Current 24 hour Day)
4. HistDay (History Day)
5. Quarter (15 minute interval)
[F2] Reset : to clear the selected PM type
[F5] Reset All : to clear all the PM type
CV = Code Violation
ES = Errored Seconds
SES = Severely Errored Seconds
UAS = UnAvailable Seconds
System Name: Aggregate/Local
[F3] PM Type: HistQuart [F4] Range: 1~12 Valid Quart:3 Day:0
[F1] Line Path
+-----------------------------------------------------------------------------+
|Quarter Id CV ES SES CV ES SES UAS ALM |
| 1 - 90 0 0 0 0 90 |
| 2 - 0 0 0 0 0 0 |
| 3 - 0 0 0 0 0 0 #|
| 4 - 0 0 0 0 0 0 #|
| 5 - 0 0 0 0 0 0 #|
| 6 - 0 0 0 0 0 0 #|
| 7 - 0 0 0 0 0 0 #|
| 8 - 0 0 0 0 0 0 #|
| 9 - 0 0 0 0 0 0 #|
| 10 - 0 0 0 0 0 0 #|
| 11 - 0 0 0 0 0 0 #|
| 12 - 0 0 0 0 0 0 #|
+-----------------------------------------------------------------------------+
+-----------------------------------------------------------------------------+
| Reset[F2] Reset All[F5] Back[ESC] |