USER MANUAL
FMUX04
Fiber Optical Multiplexer
Standalone / Rack Type
4 Channel Fixed Design
G.703 E1, T1(DS1)
SNMP Manageable (Optional)
FXS Order Wire (Optional)
Vue de la page 0
1 2 3 4 5 6 ... 61 62

Résumé du contenu

Page 1 - USER MANUAL

USER MANUAL FMUX04 Fiber Optical Multiplexer Standalone / Rack Type 4 Channel Fixed Design G.703 E1, T1(DS1) SNMP Manageable (Optional) FXS Order

Page 2

Chapter 1: Introduction The following photo (AC model), with graphics, shows the major components which make up the FMUX04 (with the Order Wire and S

Page 3

Chapter 1: Introduction 11 1.5 Technical Specifications 1.5.1 E1 Link Ports 4 fixed ports Framing Unframed (transparent) Bit Rate 2.048 Mb/s +/-50

Page 4

Chapter 1: Introduction 12 1.5.3 Local Setup and Configuration DIP Switches A switch -12 pole, B switch - 2 pole Console Port local VT-100 terminal

Page 5 - Table of Contents

Chapter 1: Introduction 13 1.5.6 Optical Specifications Connector Type ST, SC, FC, LC, MT-RJ or WDM-SC (single fiber) Optical mode Multi-mode or Si

Page 6

Chapter 1: Introduction 14 1.5.9 Power supply Voltage (AC source) 100 ~ 240 VAC Voltage (DC range 1) 18 ~ 36 VDC Voltage (DC range 2) 36 ~ 72 VDC

Page 7 - Chapter 1. Introduction

Chapter 1: Introduction 1.7 T1(DS1) Signal Structure 1.7.1 T1 link line rate The T1 line operates at a nominal rate of 1.544Mb/s. 1.7.2 T1 link lin

Page 8

Chapter 1: Introduction 16 This page left blank intentionally.

Page 9

Chapter 2. Installation Chapter 2. Installation 2.1 General The Installation chapter will cover the physical installation of the FMUX04, Standalone/R

Page 10 - Chapter 1: Introduction

Chapter 2. Installation 2.4 Mechanical Assembly The FMUX04 is designed for standalone use, but it may be rack mounted as required with an optional mo

Page 11

Chapter 2. Installation 2.5 Electrical Installation 2.5.1 Power connection, AC For a model with AC power supply, AC power (100~240VAC) is supplied to

Page 13

Chapter 2. Installation 2.6 Rear Panel Connectors The rear panel of the FMUX04 supports the E1 and T1 interface connection, the AC or DC power connect

Page 14

Chapter 2. Installation 2.8 Removal/Replacement Procedures 2.8.1 Order Wire Feature Module Removal / Replacement ***CAUTION*** This procedure should

Page 15

Chapter 2. Installation 2.8.2 SNMP Feature Removal / Replacement ***CAUTION*** This procedure should only be performed by qualified service personne

Page 16

Chapter 3. Operation 23 Chapter 3. Operation 3.1 Introduction This chapter will go into the details of the specific configuration and operation of the

Page 17 - Chapter 2. Installation

Chapter 3. Operation 3.3 Terminal Mode Operation 24 A notebook computer has become an invaluable tool of the Systems Engineer. Connection between th

Page 18

Chapter 3. Operation 3.5 Configuring in Console Mode The FMUX04 Control Port (labeled Console & Alarm on the front panel) is a console terminal

Page 19

Chapter 3. Operation If a password is required to login, please enter the 4 digit password previously set. Please see 3.5.2.1 System Configuration re

Page 20

Chapter 3. Operation The display window shows the status for both the local and remote multiplexers. If the optical link is broken, the remote status

Page 21

Chapter 3. Operation 3.5.2.1 System Configuration Use the System Configuration menu option to save and load the single user setting, to load the fact

Page 22

Chapter 3. Operation Loopback Descriptions * LLB (Optical local loop back) near end (NE) far end (FE) * RLB (Optical Remo

Page 23 - Chapter 3. Operation

The information contained in this document is subject to change without prior notice. TRADEMARKS Microsoft is a registered trademark of Microsoft C

Page 24

Chapter 3. Operation 3.5.2.3 E1/T1 Configuration LOCAL << E1/T1 Configuration >> 1.

Page 25

Chapter 3. Operation * RLB (E1/T1 Remote loop back) near end (NE) far end (FE) This remote loop back will loop the logical chan

Page 26

Chapter 3. Operation 3.5.2.5 Alarm Relay The fifth item from the ''Configure System Status' menu is the Alarm Relay Co

Page 27

Chapter 3. Operation 3.5.2.7 SNMP Configuration Please refer to Chapter 4 SNMP for the configuration of the SNMP option. 3.5.2.8 Upgrade firmware us

Page 28

Chapter 3. Operation Upgrade Procedure Select the upgrade option; "1" upgrade the mainboard firmware, or "2" upgrade the FPGA firm

Page 29

Chapter 3. Operation 3.5.3 Display Alarm Record From the main login page, press "3" to display the alarm record. The

Page 30

Chapter 3. Operation 3.6 Remote Configuration From the main login page select the second option "2", Remote Login. REMOTE

Page 31

Chapter 4. SNMP 37 Chapter 4. SNMP 4.1 General The Simple Network Management Protocol (SNMP) is one of many protocols in the Internet Protocol (IP)

Page 32

Chapter 4. SNMP 38 The MIB includes the definitions of relevant managed objects (MIB variables) for the specific node. Various MIB's can be defi

Page 33

Chapter 4. SNMP In general, SNMP agents support two types of access rights: Read-only the SNMP agent accepts and processes only SNMP getRequest an

Page 34

CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60, Zhouzi St. Neihu, Taipei, 114 Taiwan Phon

Page 35

Chapter 4. SNMP 4.6.1 Configure the SNMP Agent From the 'SNMP Configuration' menu select "1", SNMP Agent Configuration.

Page 36

Chapter 4. SNMP The manager configuration has the ability to setup access for up to four (4) different management workstations. The community strings

Page 37 - Chapter 4. SNMP

Chapter 4. SNMP 4.6.4 Save Configuration and Reboot the SNMP From the 'SNMP Configuration' menu, press "4" to sav

Page 38

Chapter 4. SNMP Make sure the TFTP server is running and enter your choice of upgrade item. LOCAL <

Page 39

Chapter 4. SNMP CTC Union provides a TFTP utility program that runs standalone in Windows® without any installation. We recommend that you copy the p

Page 40

Chapter 4. SNMP 4.7 MIB File A MIB is a "management information base" file that allows network management software understand how to manage

Page 41

Chapter 4. SNMP 4.8 Web Based Interface When the FMUX04 is installed with the SNMP option, the unit has the added management features of Telnet, SNMP

Page 42

Chapter 4. SNMP 4.8.3 Display System Status The default page shown will be the Display System Status page. Note that the navigation menu is in the fra

Page 43

Chapter 4. SNMP 4.8.5 System Configuration The System Configuration page is used to save and load user settings, load default settings, clear the alar

Page 44

Chapter 4. SNMP 4.8.7 E1/T1 Configuration The E1/T1 configuration page sets the channel service, line code and termination type for the E1/T1. It also

Page 45

Table of Contents i Chapter 1. Introduction...

Page 46

Chapter 4. SNMP 4.8.9 Alarm Configuration The Alarm Relay page allows enabling or disabling the alarm relay function. (refer to 3.5.2.5)

Page 47

Chapter 4. SNMP 4.8.11 SNMP Setup 4.8.11.1 SNMP Agent Configuration Configures the agent IP, subnet mask and default gateway. (refer to 4.6.1)

Page 48

Chapter 4. SNMP 4.8.11.3 TFTP Server Configuration Configures the SNMP card for TFTP upgrade. (refer to 4.6.3) 4.8.11.4 Save Conf

Page 49

Chapter 4. SNMP 4.8.11.5 TFTP and Upgrade Firmware Once TFTP is properly configured, this page is used to execute the upgrade for SNMP, mainboard firm

Page 50

Chapter 4. SNMP 4.8.13 Display Information The Display Information page is where the current versions for main firmware, FPGA and SNMP can be displaye

Page 51

Chapter 4. SNMP 55 Set IP login Password The above examples are Telnet using Windows HyperTerminal utility. The scr

Page 52

Appendix A. Miscellaneous Appendix A. Miscellaneous A.1 Console port pin assignment The console port on the FMUX04 serves two purposes; it provides th

Page 53

Appendix A. Miscellaneous A.3 Console cable pin assignment CAB-DB9DB9F-232-3 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 DB9F

Page 54

Appendix A. Miscellaneous A.6 SNMP RJ-45 pin assignment Pin Signal Description 1 TX+ Transmit (+)* 2 TX- Transmit (-)* 3 RX+ Receive (+)* 4 NC No

Page 55

Appendix A. Miscellaneous 59 A.8 SNMP Object Details Path=iso.org.dod.private.enterprise.ctc.fmux04.local Object Identifier Object Type stat Parame

Page 56 - Appendix A. Miscellaneous

Table of Contents ii 3.5.2 Define System Parameters ... 27 3.5.3 Di

Page 57

Appendix A. Miscellaneous 60 Object Identifier Object Type stat Parameters local_phone_configuration RW 0 - off 1 - on local_alarm_relay R

Page 59

Fiber Converter Series CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology

Page 60

Chapter 1: Introduction 7 Chapter 1. Introduction Thank you for choosing the FMUX04. If you would like to skip right to the installation and configura

Page 61

Chapter 1: Introduction 8 When configured for E1 operation, the 4 channels of the FMUX04 may use either BNC (75 Ohm unbalanced) or RJ-45 (120 Ohm bal

Page 62 - Fiber Converter Series