Setup Data Parameter, Data Rate
For Data data rate, the default setting is N=32. The date rate can be adjusted in increments of 64kbps from
64kbps to 2304kbps (N=1~36).
Setup Data Parameter, Clock Polarity
The data port clock polarity may be adjusted to solve some rare clocking issues that can result from varying
cable lengths. The default setting is 'Normal' clock polarity, where data is sent on the positive transition of the
clock, while the option exists to set inverse clock polarity where data is sent on the negative clock transition.