3.2.10 Logout
Logging out will ensure that the management session with FRM220-1000MS is terminated. This is especially important if you are using a
public computer to manage the device. Once logged out, a password must be entered to access FRM220-1000MS again.
Click the “OK” button to completely log out. Click the “Cancel” button to return to configuration of FRM220-1000MS.
3.3 Troubleshooting
3.3.1 Factory Default.
Apply power to FRM220-1000MS and allow 25-30 seconds to fully boot. Using a pencil or ball-point pen, press the 'DEFAULT' recessed
push-button switch (located on the face plate) and hold for 6 seconds or more then release. DO NOT POWER OFF; Allow the unit to again
fully reboot (about 25 seconds). The factory default TCP/IP settings are:
IP=10.1.1.1
netmask=255.255.255.0
GW=10.1.1.254
The username and password are both reset to 'admin'.
Additionally, any VLAN, 1Q or Q in Q will be disabled. All ports will be enabled, UTP ports set for auto-negotiation and no bandwidth
limiting on any port.