3.2.3.2Ping Test
With FMC-1000M(S) reset to factory default, connect a PC and configure the PC to the 10.1.1.0 network (10.1.1.100 recommended). Use a
PC to ping FMC-1000M(S) at its factory default IP address of 10.1.1.1. With a direct connection to PC, there should be no time outs and ping
latency should be less than 1 millisecond. If you switch to another FMC-1000M(S), be sure to clear the PC ARP table. Every FMC-1000M(S)
has the same default IP address, but every unit has a different MAC address. To clear the PC’s MAC table, open a command window and
execute the command ‘arp –d’. In addition, if you disconnect the PC from any LAN connection and then re-connect, the ARP table should also
be cleared.
3.2.3.3 Web Access Test
With FMC-1000M(S) reset to factory default, connect a PC and configure the PC to the 10.1.1.0 network (10.1.1.100 recommended). Use a
PC to connect to FMC-1000M(S) at its factory default IP address of 10.1.1.1 using a web browser (Internet Explorer, Firefox, Chrome, etc.).
The local web page login page should display. Use ‘admin/admin’ to login; the local main page should be displayed in the browser.
If the ping test can pass and the login page can be displayed but login fails, we recommend that cookies be deleted. You may either delete
all cookies for your browser or only the individual cookie created for the IP address of FMC-1000M(S).